Downloads
- CAD Sections & Document

NEW
Milbank Air Mattress Safety Systems

Brochure
request
|
|
|
| Floor
Quotation Checklist |
To
enable us to give you the most accurate estimate for your project we need
certain information.
On
this page you can find a checklist. Much of this information may be included
in your drawings - but some may not, so please print this page for your
reference and check.
If
you have any questions, or are simply looking for a quick estimate of
costs, please email or call
us on 01787 223931.
|
SCROLL
DOWN OR CLICK LINKS
Contact info &
access
The floor itself
The floor & walls
The floor & stairs
The floor & voids and
openings
The floor and steelwork
OTHER
PAGES
Contact Details
|
| Checklist
Part
1 - General Information |
| Enquirers
name and contact details and details of who the quote is to be sent
to (if different) |
|
| Site
address and location for the development |
Location
can affect haulage costs |
| The
area to be covered by the precast floor and the level of the floor
(ground/ ground over basement/ first floor/ second floor/ etc...) |
To
ensure that the correct area of floor is quoted for |
| Are
there any access or delivery restrictions? (E.g. are rgid lorries
required, would delivery be required outside normal working hours?) |
Working
hours can affect the haulage and fixing costs |
Top
|
| Checklist
Part
2 - The Floor |
| The
use to which the precast floor is to be put (i.e. domestic, games
room, garage, office, storage, etc...) |
To
ensure floors is designed for correct loadings |
| The
superimposed (live) load that is required by the Architect/ Engineer. |
To
ensure floors is designed for correct loadings |
| The
depth and type of floor finish that is to be applied to the precast
floor. (E.g. 50mm screed, 75mm screed, chipboard and polystyrene,
raised access flooring etc.) |
To
ensure floors is designed for correct loadings |
| The
type of cieling finish to be applied to the underside of the precast
floor where applicable. |
To
ensure floors is designed for correct loadings |
| The
direction that the precast floor units are to span between supports. |
To
ensure floors span onto load bearing elements |
| Internal
dimensions between supporting walls, or centrelines of steelwork. |
To
determine span of floor units |
| Perimeter
edge details (E.g. do floors cantilever over supports?) |
To
determine extent of precast floor area. |
Top
|
| The
type of thickness of the wall(s) that the precast floor units bear
onto, both below and above the floor level. |
To
ensure that floors have the correct bearing at the supports |
| The
type and thickness of finish to be applied to the wall(s) supported
on the precast floor units. |
To
ensure that the floors ate designed to carry the partitions |
| If
the wall(s) to be supported by the precast floor units carry load
from above, what is the load to the wall(s) and /or what do the walls
support. |
To
ensure that the floors are designed to carry the load bearing walls |
Top
|
|
Are
the stairs supported off the precast floor, if so what type and
span are the stairs. (i.e. timber, precast concrete etc)
|
To
ensure that the floors are designed to carry the stairs |
| A
plan of the stairwell |
To
establish the size of the landings and how they are to be supported |
| A
section through the stairwell showing the finished floor to finished
floor dimension of each storey. |
To
establish the Rise and Going of the flights |
| What
is the depth of finishes at each floor level? |
To
allow correct size and positioning of the top and bottom risers. |
Top
|
| Checklist
Part
5- Voids
and openings |
| The
location and sizes of soil/vent pipes, gas, water mains etc. |
To
make adequate provision in the layout of the precast floor units |
| Size
and position of all large voids and openings required in the precast
floor |
To
make adequate provision in the layout of the precast floor units |
|
Types
and sizes of steel trimmers provided in the supporting structure
|
|
Top
|
| Checklist
Part
6- Steelwork |
| Layout
and dimensions to all steelwork |
|
| The
size and level of all steelwork, and type of support to the precast
floor units. |
|
|
Size,
type and location of any surrounds to column, beams etc.
|
|
Top
|
 |
printed